• (044) 797 2524

Aplicaciones Tecnológicas – DAT CONTROLER® REMOTE Smart air terminal

DAT CONTROLER® PLUS evolved to its DAT CONTROLER® REMOTE version with the addition of IoT connectivity, allowing self-assessment and daily communication of the lightning rod status, thus making it the first smart lightning arrester on the market.

 

Description

Smart Lightning Protection

DAT CONTROLER® REMOTE

Smart Early Streamer Emission (ESE) Air Terminal

DAT CONTROLER REMOTE smart lightning air terminal in rainy conditions

Intelligent lightning protection with remote status monitoring

DAT CONTROLER® REMOTE combines Early Streamer Emission (ESE) lightning protection with built-in self-diagnostics and Internet of Things (IoT) connectivity.

The air terminal automatically evaluates its own status and communicates results daily to the AT-CLOUD platform, supporting preventive and corrective maintenance.

Key Features

Automatic self-diagnosisAutonomously evaluates the air terminal’s status and reports the result daily.
IoT connectivityTransmits status information to AT-CLOUD and supports on-demand status queries.
Remote visualizationView installation data, air terminal status, and communication history through a web portal.
Tested performanceManufacturer-reported testing includes rainy conditions and extended lightning-current stress tests.

How Remote Monitoring Works

The lightning air terminal carries out its own diagnostic check and sends the results to the AT-CLOUD server. Users can review its condition from a connected device and receive customized notifications.

The platform can display installation coordinates, serial number, last communication date and time, and air terminal status test results (OK, Check, or Not Connected).

Technical and Compliance Highlights

Technology Early Streamer Emission (ESE) air terminal
Remote functions Daily self-diagnosis, IoT communication, AT-CLOUD status visualization and custom notifications
Communications Manufacturer lists 2G, 3G, LTE-M and NB-IoT technologies
ESE standard UNE 21186:2011; manufacturer also lists related standards including NF C 17-102:2011
Product certification AENOR N Product Certification No. 058/000005, as stated by the manufacturer
Rain performance Manufacturer states certified insulation greater than 95% in accordance with UNE-EN 60060-1:2012

Protection radius depends on installation geometry, lightning protection level and applicable ESE calculation standards; no fixed radius is stated here.

Installation Considerations

ESE air terminals must be installed according to the applicable lightning protection standard and engineered for the site. The manufacturer’s guidance references UNE 21186 installation requirements.